Strona 1 - Gas Rethermalizers

Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 819-5278 24-Hour Service H

Strona 2

2-2 This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped “NAT” only to

Strona 3

2-3 After the unit has been positioned in the area where it will be used, ensure the following has been accomplished before connecting the unit to the

Strona 4 - TABLE OF CONTENTS

2-4 2.4 Connecting to the Gas Supply GAS CONNECTIONS AND PIPE SIZES The size of the gas supply pipe is very important. If the pipe is too small, t

Strona 5

2-5 WARNING “Dry-firing” this equipment will cause damage to the cookpot. Always ensure that the cookpot is filled with water before firing your uni

Strona 6

3-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 3: OPERATING INSTRUCTIONS 3.1 Introduction Mechanically, the FBR18 and FBRA18 rethermalizer

Strona 7 - 1.5 Definitions

3-2 NOTE: The unit comes from the factory configured to display in degrees Fahrenheit. To toggle back and forth between Fahrenheit and Celsius, press

Strona 8

3-3 1. Turn the gas valve to the ON position (see illustration below). OFFONHoney well 2. Press the controller Power switch. On FBR18 models,

Strona 9 - Frymaster WARRANTY

3-4 4. After the solution simmers for an hour, turn the unit off, allow the solution to cool, then add 2 gallons (7.75 liters) of cold water and stir

Strona 10 - FCC COMPLIANCE

4-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 4: PREVENTIVE MAINTENANCE 4.1 Daily Checks and Services Inspect Rethermalizer and Accesso

Strona 11 - Incoming Gas Pressures

4-2 4.2 Quarterly Checks and Services Check Digital Controller Set Point Accuracy 1. Fill the cookpot with water. Press the controller power switc

Strona 12

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DI

Strona 13

4-3 open or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in position and retighten the nut(s). C

Strona 14 - Frymaster

4-4 3. Place the gas valve in the ON position. Place the controller power switch in the ON position. When the burner lights and continues to burn,

Strona 15

5-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 5: OPERATOR TROUBLESHOOTING 5.1 Introduction This chapter provides an easy reference guide

Strona 16 - Honey well

5-2 5.2 Troubleshooting Guides COOKPOT DID NOT FILLWHEN UNIT WAS TURNED ON.WATER SUPPLY TO UNITVERIFIED TO BE ON.Did anything appearin controller d

Strona 17 - Hon e ywell

5-3 WATER DID NOT SHUTOFF WHEN COOKPOTWAS FULL.Use bottlebrush to cleanwater level sensors.Did waterstop?Problemresolved.Add 1/8 cup of salt towater

Strona 18

5-4 WATER NOT HEATING.AUTOFILL (IF INSTALLED)WORKED PROPERLY.Press the TemperatureCheck button twice todisplay setpoint.Has the correct setpointbeen

Strona 19

5-5 BURNERS DONOT LIGHT.Verify that correct setpoint hasbeen programmed, that main gassupply valve is open, and thatequipment gas valve is set to ON.

Strona 20

5-6 5.3 Replacing the Controller or Controller Wiring Harness 1. Disconnect the rethermalizer from the electrical supply. 2. Remove the two scre

Strona 21 - Pressures

6-1 Inside the Ignition ModuleTDOut toGas ValveTo Alarm25 V +25 V GNDHVIgnition Wire Flame SensorCoilFBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAP

Strona 22

6-2 guished), current to the ignition module is cut, preventing the main valve from opening, and the igni-tion module “locks out” until the power swit

Strona 23 - 5.2 Troubleshooting Guides

DANGER Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications can cause property damage, injury, o

Strona 24

6-3 The relays in earlier design boards are soldered on and cannot be replaced. Later design boards fea-ture replaceable plug-in relays. In earlier

Strona 25

6-4 6.2 Accessing the Rethermalizer for Servicing DANGER Moving a rethermalizer filled with hot water may cause spilling or splattering of the hot w

Strona 26

6-5 6.6 Replacing Components 6.6.1 Replacing the Controller or Controller Wiring Harness Refer to Chapter 5, Section 5.3 for this procedure. 6.6.2 R

Strona 27 - Ground Wire

6-6 5. On FBRA18 models only, mark the water level sensor wires and disconnect them from terminals J1-1 (upper sensor) and J1-2 (lower sensor). 6.

Strona 28 - Inside the Ignition Module

6-7 6.6.6 Replacing the Combustion Air Blower Refer to Chapter 4, Section 4.4, Clean Combustion Air Blower, for instructions on removing and re-insta

Strona 29

6-8 4. Remove the four screws from the blower stabilizing bracket attached to the blower assembly and to each burner. Remove the stabilizing bracket

Strona 30 - INTERFACE BOARD P/N 806-9592

6-9 knowledge of possible problems, and the probable causes of each. With this knowledge, the techni-cian should be able to isolate and correct any p

Strona 31 - Flame Sensor

6-10 tion failure situation may be encountered in which all components appear to be serviceable and the microamp reading is within specification, but

Strona 32

6-11 If popping is consistent during all hours of operation, the most likely cause is an insufficient air sup-ply. Check for “negative pressure” con

Strona 33

6-12 6.7.3 Improper Temperature Control Temperature control is a function of several interrelated components, each of which must operate correctly.

Strona 34

i FBR18 & FBRA18 SERIES GAS RETHERMALIZERS TABLE OF CONTENTS CHAPTER 1: General Information 1.1 Parts Ordering and Service Information ...

Strona 35

6-13 6.8.1 Troubleshooting the Gas Valve NOTE: All voltage measurementsmust be made within 4 seconds ofunit calling for heat. If unit doesnot fire

Strona 36 - TROUBLESHOOTING THE 24 VAC

6-14 6.8.2 Troubleshooting the 24 VAC Circuit in FBR18 Units NOTE: All voltage measurements mustbe made within 4 seconds of unitcalling for heat. I

Strona 37

6-15 THE 24 VAC CIRCUIT IN FBR18 UNITS 24VTRANSFORMERBLOWERCENTRIFUGALSWITCHRIGHTIGNITIONMODULELEFTIGNITIONMODULEGASVALVEJ3 PIN 8LED3 (24V)RELAY K2 ON

Strona 38

6-16 6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units UNIT IS CONNECTED TOPOWER SUPPLY, DRAINVALVE IS FULLY CLOSED,NO WATER IS IN POT,CONTROL

Strona 39

6-17 6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued) NOTE: All voltage measurements involving thegas valve leg of the 24V circu

Strona 40

6-18 6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued) NOTE: All voltage measurements involving thegas valve leg of the 24V circu

Strona 41

6-19 6.8.3 Troubleshooting the 24 VAC Circuit in FBRA18 Units (Continued) NOTE: All voltage measurements must bemade within 4 seconds of unit callin

Strona 42 - TRANSFORMER

6-20 THE 24VAC CIRCUIT IN FBRA18 UNITS 24VTRANSFORMERJ2 PIN 4LEDPOWERLATCHRELAYINTERFACE BOARDLOGIC CIRCUITRYJ2 PIN 3J2 PIN 2 J1 PIN 3LEDWATERWATERSO

Strona 43

6-21 6.8.4 Troubleshooting the Temperature Probe WHILE IT IS STILL INTHE COOKPOT,INSPECT THE PROBEBODY FOR DAMAGE.REPLACE IF BENT,DENTED, OR CRACKED.

Strona 44

6-22 FOHMSC FOHMSC FOHMSC FOHMSC FOHMSC32 1000 0 83 1107 28 134 1214 57 185 1320 85 236 1424 11333 1002 1 84 1110 29 135 1216 57 186 1322 86 237 1426

Strona 45

ii Temperature Probe ... 6-3 Water Level S

Strona 46

6-23 6.9 Wiring Diagram for FBR18 Units 581110129764312GNDGND321SOUNDGNDV1SALRMPWRV1DGNDGNDV2SA SA DPWRV2DGNDGREENJ210 11 12CENT.SWITCHCNCNOJ31C 3C 8

Strona 47

6-24 6.10 Wiring Diagram for FBRA18 Units IGNITORIGNITION MODULEGAS VALVEHIGH VOLTAGE LEAD.AS ITS MATCHINGTO THE SAME IGNITORMUST BE CONNECTEDFLAM

Strona 48

7-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 7: PARTS LIST 7.1 Burner System Components 123456 ITEM PART # COMPONENT Burner Assemb

Strona 49 - Probe Resistance Chart

7-2 7.2 Cabinetry and Associated Components 12345678109141511121316211718192022 ITEM PART # COMPONENT 1 910-1181 Retainer, Flue Cap Insulation2 816

Strona 50 - 8050417D

7-3 7.3 Control Box Assembly and Associated Parts, FBR18/ FBRA18 BLACKWHITELEFT IGNITOR RIGHT IGNITOR5678432125V(GND)ALARMVALVEGND(BURNER)25V 25V(BUR

Strona 51 - 8051017B

7-4 7.4 Controller and Component Box Assemblies GND GNDSOUND12GND213467912101185132645978121011J3Frymaster- - - -CF12457338GND3J1GNDV1DPWRALRMV1SGNDV

Strona 52 - CHAPTER 7: PARTS LIST

7-5 7.5 Cooking Timer Control Panel Components Error! Not a valid link. ITEM PART # COMPONENT 1 910-4496 Cooking Timer Control Panel 2 Knob Ass

Strona 53 - ITEM PART # COMPONENT

7-6 7.6 Cookpot, FBR18 67891012345 ITEM PART # COMPONENT 1 900-1762 Retainer, Insulation 2 900-7431 Cover, Cookpot Front Insulation 3 816-0143 I

Strona 54 - RIGHTLEFT

7-7 7.7 Cookpot, FBRA18 8910111213This washer must beseated in hole beforenut is tightened.Torque nut to30 in-lb ± 5.Inside face ofcookpot.Enlarged Vi

Strona 55

7-8 7.8 Gas Supply Components 151413121110123456798 ITEM PART # COMPONENT 1 Gas Valve 810-0786 Natural Gas 810-0787 LP (Propane) Gas 2 813-0

Strona 56 - Error! Not a valid link

1-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 1: GENERAL INFORMATION 1.1 Parts Ordering and Service Information In order to assist you a

Strona 57

7-9 7.9 Plumbing Components 5167341028912111316151417201819 ITEM PART # COMPONENT 1 806-9067 Valve Assembly, Solenoid (FBRA18 only) 2 810-1208 V

Strona 59

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106

Strona 60

1-2 CAUTION CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system. WARNING WARNING

Strona 61

1-3 QUALIFIED INSTALLATION PERSONNEL Qualified installation personnel are individuals, or firms, corporations, or companies which, either in person o

Strona 62 - May 2003

2-1 FBR18 & FBRA18 SERIES GAS RETHERMALIZERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2.1 General Installation Requirements PROPER INSTALLATION IS